Operation Installation and Operation Handbook
2-12
408 and 2404 Controller
PARAMETER TABLES
Name Description
Home list
Home Measured value and Setpoint
OP
OPOP
OP
% Output level
SP
SPSP
SP
Target setpoint (if in Manual mode )
m
mm
m-
--
-A
AA
A
Auto-man select
AmPS
AmPSAmPS
AmPS
Heater current (With PDSIO mode 2)
C.id
C.idC.id
C.id
Customer defined identification number
+ Extra parameters, if the ‘Promote’ feature has been used (see Chapter 3, Edit Level).
run
runrun
run
Program run list − Present only in setpoint programming controllers
PrG
PrGPrG
PrG Active program number (Only on 4, or 20, program versions)
StAt
StAtStAt
StAt Program status (OFF, run, hoLd, HbAc, End)
PSP
PSPPSP
PSP
Programmer setpoint
CYC
CYCCYC
CYC
Number of cycles remaining in the program
SEG
SEGSEG
SEG
Active segment number
StyP
StyPStyP
StyP
Active segment type
SEG.t
SEG.tSEG.t
SEG.t
Segment time remaining in the segment units
tGt
tGttGt
tGt
Target setpoint
rAtE
rAtErAtE
rAtE
Ramp rate (if a rate segment)
PrG.t
PrG.tPrG.t
PrG.t
Program time remaining in hours
FASt
FAStFASt
FASt Fast run through program (no / YES)
out.n
out.nout.n
out.n Event output states (OFF / on) (not 8-segment programmer)
SYnc
SYncSYnc
SYnc Segment synchronisation (no / YES) (not 8-segment programmer)
SEG.d
SEG.dSEG.d
SEG.d Flash active segment type in the lower readout of the home display (no / YES)